Malaysia
Contact Us
About Us
Login
|
Register
Search Keyword, Item or Model
Press
to jump to the search box
Shopping List
0
Cart
View All Categories
View All Brands
View All Spec Tables
USD - US$
Home
/
All Categories
/
Electrical Testing & Measuring
/
Clamp Meters
/
Multi M-730CE AC/DC Clamp Miliammeter
View Brand
Multi M-730CE AC/DC Clamp Miliammeter
Brand:
Multi
Model:
M-730CE
Product Description
Multi M-730CE AC/DC Clamp Miliammeter
Withstanding Voltage:
AC 3700V/1 minute between CT and outer case
Storage Temperature:
-10~60℃, < 70%RH (without condensation)
DC Current
Accuracy (23℃±5℃, less than 85%RH):
Range/Measuring Range/Resolution/Accuracy
100mA: 0.1~±99.99mA / 0.01mA / ±1%rdg±10dgt
1000mA: 1~±300mA / 0.1mA / ±1%rdg±10dgt
1000mA: ±300.1~±700mA / 0.1mA / ±2%rdg±10dgt
1000mA: ±700.1~±999.9mA / 0.1mA / ±3%rdg±10dgt
Influence of terrestrial magnetism: Less than ±2.0mA
Influence of magnetization: Less than ±2.0mA by DC 1.5A on/off
Influence of CT opening and closing: Less than ±1.0mA
Max. input current: DC 1.5A
AC Current
Accuracy (23℃±5℃, less than 85%RH):
Range/Measuring Range/Resolution/Accuracy
100mA: 0~99.99mA / 0.01mA / ±2%rdg±10dgt (50/60Hz)
1000mA: 0~999.9mA / 0.1mA / ±2%rdg±10dgt (50/60Hz)
10A: 0~9.999A / 0.001A / ±1%rdg±10dgt (50/60Hz)
Max. input current: AC 20A
Operating Temperature:
0~50℃, < 85%RH (without condensation)
Power supply:
LR6, AM-3 or AA size battery×4
Dimension:
Main unit: 78(W)×155(H)×32(D)mm, Approx. 280g
CT (CTP-30DC): 1.2m lead, Approx. 165g
AC Conversion:
Average sensing rms reading
Safety standard:
IEC61010-1, IEC61010-2-032 CATⅡ 600V or CATⅢ 300V
Jaw opening capability:
30mmφ
Limitation of circuit voltage:
Less than AC/DC 600V
Accessories:
Carrying case, Batteries, Instruction manual
Current Consumption:
Approx. 9mA (Approx. 200 hours continuous)
Option:
Cable for recorder
Sampling rate:
1 time/sec. for DC and 6 times/sec. for AC
Display:
Max. 2000 count on LCD with annunciators
Measuring function:
AC/DC leakage current
A/D Conversion:
Dual slope integration method
Over range indication:
"OL" mark on LCD
Data hold indication:
"DH" mark on LCD
Low battery indication:
"Battery" mark on LCD
Analog signal output:
DC 100mV full scale to each range (Output impedance: less than 10kΩ)
Auto power off:
Approx. 10 minutes after last switch operation (Auto power off function can be released by the switch)
Measuring method:
Clamp type CT
Zero adjustment:
For DC current range by "0 ADJ" switch
US $ 926.48
Quantity:
EA
Add to Cart
Add To Shopping List
This item is sold by
MY-1614015247
View Shop
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Clamp Meters from Multi
Source & compare similar products
More from Clamp Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Top