Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Schneider Electric A9MEM3335 125 a - iEM3335 Energy Meter
Schneider Electric A9MEM3335 125 a - iEM3335 Energy Meter
Image
Image
Specifications
infotip-icon
View other Power & Energy Meters dimensions or variations
Please select at least one specification below.
Range
Acti9
Poles Description
3P 3P + N 1P + N
[In] Rated Current
125 A
Type of Measurement
Active and reactive energy Active and reactive power Current Voltage
Rated Voltage
100…277 V 173…480 V
Display Type
LCD display
Standards
BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62052-23 IEC 62053-23:2020 EN 62052-23 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 BS EN 50470-3 EN 50470-3 BS EN 50470-1 EN 50470-1 ANSI C12.16
Ambient Air Temperature for Operation
-25…55 °C - MID -25…70 °C - IEC
Colour
White
This spec is not available in the specification table.
Width
126 mm
This spec is not available in the specification table.
Local Signalling
Green indicator light: power ON Yellow flashing LED: accuracy checking alarm: overload
This spec is not available in the specification table.
Device Short Name
iEM3335
This spec is not available in the specification table.
Product or Component Type
Energy meter
This spec is not available in the specification table.
Range of Product
Acti9 iEM3000
This spec is not available in the specification table.
Depth
69.3 mm
This spec is not available in the specification table.
Device Application
Sub billing Multi-tariff Partial meter
This spec is not available in the specification table.
Mounting Support
DIN rail
This spec is not available in the specification table.
Height
103.2 mm
This spec is not available in the specification table.
Mounting Mode
Clip-on
This spec is not available in the specification table.
Accuracy class
Class 1 active energy conforming to IEC 62053-21 Class 1 active energy conforming to IEC 61557-12 Class B active energy conforming to EN 50470-3
This spec is not available in the specification table.
input type
Direct input
This spec is not available in the specification table.
Network Frequency
60 Hz 50 Hz
This spec is not available in the specification table.
Technology Type
Electronic
This spec is not available in the specification table.
Sampling rate
32 samples/cycle
This spec is not available in the specification table.
Measurement current
0…125 A
This spec is not available in the specification table.
Maximum value measured
99999999.9 kWh
This spec is not available in the specification table.
Communication Port Protocol
M-bus at 300, 600, 1200, 2400, 4800 and 9600 bauds, insulation 3750 V
This spec is not available in the specification table.
Communication port support
Screw terminal block: M-Bus
This spec is not available in the specification table.
Number of inputs
1 digital 0...5 V/11...40 V 24 V DC
This spec is not available in the specification table.
Number of outputs
1 digital (static)
This spec is not available in the specification table.
Connections - Terminals
Screw terminals 50 mm² cable(s)
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
9 mm Pitches
14
This spec is not available in the specification table.
Product certifications
CE conforming to IEC 61010-1 (safety) CE conforming to EN 61557-12 (power monitor) CE conforming to EN/IEC 61326-1 (EMC) UKCA conforming to BS EN 61010-1 (safety) UKCA conforming to BS EN 61557-12 (power monitor) UKCA conforming to BS EN 61326-1 (EMC) CULus conforming to UL 61010-1 (safety) CULus conforming to EN 61010-1 (safety) EAC conforming to EN 50470-3 (sub-meter) RCM conforming to EN 62052 (sub-meter) KZ conforming to EN 50470-3 (sub-meter) METAS conforming to EN 50470-1 (sub-meter) MID conforming to EN 50470-3 (sub-meter) MID conforming to EN 50470-1 (sub-meter)
This spec is not available in the specification table.
IP Degree of Protection
IP40 front panel: conforming to IEC 60529 IP20 body: conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % at 50 °C
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
< 2000 m
This spec is not available in the specification table.
Metering type
Active, reactive, apparent energy (signed, four quadrant)
This spec is not available in the specification table.
Typical current consumption
Communication M-bus: 2.3 mA at state 1
This spec is not available in the specification table.
Output voltage
5...40 V DC@50 mA
This spec is not available in the specification table.
tariff input
Tariff (4)
This spec is not available in the specification table.
Product Description
US $ 1,041.63
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Power & Energy Meters
23 Items
power-energy-meters-img
Poles Description
3P 1P + N 3P + N, 3P + N 1P + N 3P, 1P + N 3P 3P + N, 3P 3P + N 1P + N, 3P + N 3P 1P + N
[In] Rated Current
1 A 5 A, 125 A, 63 A, 1 A 5 A 10 A, 5 A 1 A
Type of Measurement
Active energy Current Voltage Active power, Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U), Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms, Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total, Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Apparent energy total Active and reactive energy total Apparent power total Active and reactive power total Current average Voltage average Frequency average Power factor average
Display Type
Monochrome graphic LCD, Colour TFT LCD, 7 segments LED, Backlit LCD, TFT LCD
Standards
IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-24 EN 50470-3 IEC 62053-22:2020 IEC 61557-12:2015 ANSI C12.20 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, EN 50470-1 IEC 62053-24 IEC 60529 UL 61010-1 IEC 62053-22:2020 EN 50470-3 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, UL 61010-1 EN 50470-3 EN 50470-1 IEC 62053-22:2020 IEC 60529 IEC 62053-24 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20
Ambient Air Temperature for Operation
-25…70 °C meter -20…70 °C display -25…-20 °C (with reduced performance) display, -25…55 °C - MID -25…70 °C - IEC -25…60 °C - IEC, -25…70 °C - IEC, -10…60 °C, -25…70 °C
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power & Energy Meters from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power & Energy Meters
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image