Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Schneider Electric LA1KN20 Auxiliary Contact Block, Tesys K, 2NO, Front Mounting, Screw Clamp Terminals
Schneider Electric LA1KN20 Auxiliary Contact Block, Tesys K, 2NO, Front Mounting, Screw Clamp Terminals
Image
Image
Specifications
infotip-icon
View other Auxiliary Contact dimensions or variations
Please select at least one specification below.
Range
TeSys
Standard
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1
IP Degree of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature for Operation
-25…50 °C
Ambient Air Temperature for Storage
-50…80 °C
[Ue] Rated Operational Voltage
690 V AC 25...400 Hz
Pole contact composition
2 NO
Width
38 mm
This spec is not available in the specification table.
Device Short Name
LA1
This spec is not available in the specification table.
Product Name
TeSys K
This spec is not available in the specification table.
Depth
35 mm
This spec is not available in the specification table.
Connections - Terminals
Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1.5…4 mm²rigid Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²rigid
This spec is not available in the specification table.
Product certifications
CB Scheme CCC UL CSA CE UKCA
This spec is not available in the specification table.
Height
30 mm
This spec is not available in the specification table.
Operating Altitude
2000 m
This spec is not available in the specification table.
Tightening Torque
1.3 N.m - with screwdriver Philips No 2 1.3 N.m - with screwdriver pozidriv No 2
This spec is not available in the specification table.
Environmental Characteristic
Normal environment
This spec is not available in the specification table.
[Ith] conventional free air thermal current
10 A (at 50 °C)
This spec is not available in the specification table.
Irms rated making capacity
110 A at <= 690 V AC conforming to IEC 60947
This spec is not available in the specification table.
Associated fuse rating
10 A gG at <= 690 V conforming to IEC 60947
This spec is not available in the specification table.
Minimum switching voltage
17 V
This spec is not available in the specification table.
Minimum Switching Current
5 mA
This spec is not available in the specification table.
Insulation Resistance
> 10 MOhm
This spec is not available in the specification table.
Protective Treatment
TC conforming to IEC 60068
This spec is not available in the specification table.
Range compatibility
TeSys K LC1K TeSys K CA2K TeSys K CA3K TeSys K CA4K
This spec is not available in the specification table.
Permissible short-time rating
80 A 1 s 60 A 500 ms 110 A 100 ms
This spec is not available in the specification table.
Non overlap distance
0.5 mm
This spec is not available in the specification table.
Mounting location
Front
This spec is not available in the specification table.
Contacts operation
Instantaneous
This spec is not available in the specification table.
Product Description
US $ 15.14
Quantity:
EA
This item is sold by
Image
MY-0408537236
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
35 Items
auxiliary-contact-img
Rated Current
AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
Range
Acti9, EasyPact, TeSys, TeSys TeSys Deca, Tesys
Standard
UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 EN 50012, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012
[Ui] Rated Insulation Voltage
500 V, 690 V conforming to IEC 60947-5-1 600 V conforming to UL 600 V conforming to CSA, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14, 250 V conforming to CSA 250 V conforming to IEC 60947-5-1 250 V conforming to UL
Ambient Air Temperature for Operation
-25…60 °C, -35…70 °C, -20…50 °C, -25…50 °C, -5…60 °C
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz, 24...240 V AC 24...60 V DC, 48...690 V AC 24...240 V DC, 690 V AC 25...400 Hz, <= 250 V AC <= 250 V DC
Pole contact composition
2 NO + 2 NC, 4 NC, 1 NO + 3 NC, 2 NO, 3 NO + 1 NC
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from SCHNEIDER ELECTRIC
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top
Image